Symptoms

When you run a DB2 for z/OS V11 TSO Batch Utility that contains a SELECT statement, DB2 returns SQLCODE -30020 with reason code 220E.

Cause

The Microsoft Service for DRDA (DRDA Service) incorrectly processes the DRDA Sync Point Log (SYNCLOG) when the DB2 for z/OS V11 TSO batch utility (DSNTIAUL) issues a SELECT statement. This causes DB2 to interpret a DRDA protocol violation and causes DB2 to cancel the request and close the connection.

Resolution

This issue is fixed in Cumulative Update 2 for Host Integration Server 2016.

After Cumulative Update 2 is installed, the DRDA Service processes DRDA SYNCLOG in the context of the connection from a DB2 for z/OS V11 TSO batch program.

Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

References

Learn about the terminology Microsoft uses to describe software updates.

The third-party products that this article discusses are manufactured by companies that are independent of Microsoft. Microsoft makes no warranty, implied or otherwise, about the performance or reliability of these products.

Trenger du mer hjelp?

Vil du ha flere alternativer?

Explore subscription benefits, browse training courses, learn how to secure your device, and more.

Communities help you ask and answer questions, give feedback, and hear from experts with rich knowledge.

Var denne informasjonen nyttig?

Hva påvirket opplevelsen din?
Når du trykker på Send inn, blir tilbakemeldingen brukt til å forbedre Microsoft-produkter og -tjenester. IT-administratoren kan samle inn disse dataene. Personvernerklæring.

Takk for tilbakemeldingen!

×