Symptoms

The Microsoft BizTalk Adapter for DB2 can't read data that is stored in DB2 for i V7R2 GRAPHIC CCSID 13488 UNICODE UTF-16 columns. And the following message is logged in the Application event log:

Internal message: HISMPCB0001 In BasePrimitiveConverter an exception has occurred. Exception description: Object reference not set to an instance of an object. SQLSTATE HY000 with SQLCODE -343.

Cause

This issue occurs because the Microsoft DRDA Application Requester Client for DB2 doesn't convert DB2 GRAPHIC data type to the correct Microsoft .NET Framework data type.

Resolution

This issue is fixed in Cumulative Update 2 for Host Integration Server 2016.

After Cumulative Update 2 is installed, the Microsoft DRDA Application Requester Client for DB2 data conversion functionality is updated to support DB2 GRAPHIC data type.

Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

References

Learn about the terminology Microsoft uses to describe software updates.