Applies ToExchange Server 2010 Enterprise Exchange Server 2010 Standard

Symptoms

When a witness server of a Microsoft Exchange database availability group (DAG) is under a heavy workload, the Microsoft Exchange Replication service crashes on Exchange Server 2010 DAG members. Additionally, following error messages are logged on Exchange Server 2010 DAG members:

Log Name:      ApplicationSource:        MSExchange CommonDate:          DateEvent ID:      4999Task Category: GeneralLevel:         ErrorKeywords:      ClassicUser:          N/AComputer:      ComputerDescription:Watson report about to be sent for process id: Process ID, with parameters: E12, Build Type, Version, msexchangerepl, M.E.Cluster.Replay, M.E.C.A.AmHelper.GetBootTimeWithWmi, S.Management.ManagementException, XXXX, Version.ErrorReportingEnabled: TrueLog Name: ApplicationSource: MSExchangeReplDate: DateEvent ID: 2060Task Category: ServiceLevel: ErrorKeywords: ClassicUser: N/AComputer: ComputerDescription:The Microsoft Exchange Replication service encountered a transient error while attempting to start a replication instance for mailbox database\mailbox server. The copy will be set to failed. Error: The NetworkManager has not yet been initialized. Check the event logs to determine the cause.

Note If you run the following cmdlet against the witness server from the DAG members, the WMI query fails:

(Get-WmiObject -Class Win32_OperatingSystem -ComputerName Witnessservername).LastBootUpTime

Cause

This issue occurs because an OutOfMemoryException exception occurs when DAG members try to obtain the start time of the witness server by Windows Management Instrumentation (WMI). This exception causes the Microsoft Exchange Replication service to crash on the DAG members.

Resolution

To resolve this issue, install the following update rollup:

2645995 Description of Update Rollup 1 for Exchange Server 2010 Service Pack 2

Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

More Information

For more information about database availability group, visit the following Microsoft website:

General information about database availability groupFor more information about the Get-WmiObject cmdlet, visit the following Microsoft website:

General information about the Get-WmiObject cmdlet

Need more help?

Want more options?

Explore subscription benefits, browse training courses, learn how to secure your device, and more.