Cause

This issue occurs because of a by design logic in a Microsoft Exchange Server 2013 environment.

Resolution

To resolve this issue, install Cumulative Update 9 for Exchange Server 2013.

Workaround

To work around this issue, disable this probe.NoteĀ To disable this probe for all Exchange Server 2013 servers for 60 days, run the following Exchange Management Shell cmdlet:

Add-GlobalMonitoringOverrideĀ <Srting> -ItemType Probe -PropertyName Enabled -PropertyValue 0 -Duration 60.00:00:00

Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

More Information

For more information about the OwaDeepTestProbe probe, see Troubleshooting OWA.Protocol Health Set.

Need more help?

Want more options?

Explore subscription benefits, browse training courses, learn how to secure your device, and more.

Communities help you ask and answer questions, give feedback, and hear from experts with rich knowledge.