Symptoms

Users receive the following error message when trying to sign in to Microsoft Office Communicator 2007 R2:

Cannot sign in because the server is temporarily unavailable. If the problem persists, contact your system administrator.


If you restart the Microsoft Office Communications Server 2007 R2 front-end server, users can sign in to Office Communicator 2007 R2. However, users are kicked out moments later. This issue occurs when the front-end server is running on a computer with 4GB memory or a multiple of 4GB memory.

Cause

This issue occurs because the front-end server is considered to be overloaded on a computer with 4GB memory or a multiple of 4GB memory. This even occurs when there is little traffic on the server.

Resolution

To resolve this problem, install the following cumulative update:

2404547 Description of cumulative update for Office Communications Server 2007 R2: November, 2010

Workaround

Important This section, method, or task contains steps that tell you how to modify the registry. However, serious problems might occur if you modify the registry incorrectly. Therefore, make sure that you follow these steps carefully. For added protection, back up the registry before you modify it. Then, you can restore the registry if a problem occurs. For more information about how to back up and restore the registry, click the following article number to view the article in the Microsoft Knowledge Base:

322756 How to back up and restore the registry in WindowsTo work around this issue, follow these steps to create two registry keys:

  1. Click Start, type Regedit in the search box, and then press ENTER.

  2. Locate and then click the following registry subkey:

    HKEY_LOCAL_MACHINE\ System\CurrentControlSet\Services\RtcSrv\Parameters

  3. On the Edit menu, point to New, and then click DWORD (32 bit) Value.

  4. Type ProxyConnHighMark, and then press ENTER.

  5. Right-click ProxyConnHighMark, and then click Modify.

  6. Type 25000, and then click OK.

  7. On the Edit menu, point to New, and then click DWORD (32 bit) Value.

  8. Type ProxyConnLowMark, and then press ENTER.

  9. Right-click ProxyConnLowMark, and then click Modify.

  10. Type 10000, and then click OK.

  11. Exit Registry Editor.

Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

도움이 더 필요하세요?

더 많은 옵션을 원하세요?

Explore subscription benefits, browse training courses, learn how to secure your device, and more.

Communities help you ask and answer questions, give feedback, and hear from experts with rich knowledge.

이 정보가 유용한가요?

사용 경험에 어떠한 영향을 주었나요?
제출을 누르면 피드백이 Microsoft 제품과 서비스를 개선하는 데 사용됩니다. IT 관리자는 이 데이터를 수집할 수 있습니다. 개인정보처리방침

의견 주셔서 감사합니다!

×