Applies ToMicrosoft System Center 2012 R2 Configuration Manager

Symptoms

Per-computer task sequence variables that are defined for imported computers are filtered out of client policies. This prevents the variables from being read during task sequence execution. This problem does not affect per-computer variables that are defined for existing clients.

Resolution

Hotfix information

A supported hotfix is available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing the problem described in this article. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next software update that contains this hotfix.If the hotfix is available for download, there is a "Hotfix download available" section at the top of this Knowledge Base article. If this section does not appear, contact Microsoft Customer Service and Support to obtain the hotfix. Note If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers or to create a separate service request, visit the following Microsoft website:

http://support.microsoft.com/contactus/?ws=supportNote The "Hotfix download available" form displays the languages for which the hotfix is available. If you do not see your language, it is because a hotfix is not available for that language.

Installation information

This update applies only to Primary sites.Important Per-computer task sequence variables have to be re-created if they were created after System Center 2012 R2 Configuration Manager was installed but before this update is applied.

Prerequisites

To apply this hotfix, you must have Microsoft System Center 2012 R2 Configuration Manager installed.

Restart information

You do not have to restart the computer after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace any previously released hotfix.

File information

The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.

File name

File version

File size

Date

Time

Platform

Policypv.dll

5.0.7958.1103

791,216

01-Oct-2013

01:15

x64

Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

References

For more information about task sequences, see the How to Manage Task Sequences in Configuration Manager topic on the Microsoft TechNet website.See the terminology Microsoft uses to describe software updates.

Need more help?

Want more options?

Explore subscription benefits, browse training courses, learn how to secure your device, and more.

Communities help you ask and answer questions, give feedback, and hear from experts with rich knowledge.